Simple Building Life Cycle Water Usage Model
Class Name
- RSimpleBuildingLifeCycleWaterUsageModel
Location in Objects Pane
- Models > Model > Consequence > Environmental > Simple Building Life Cycle Water Usage
Model Description
Model Form
- This model produces the lifecycle water usage in a building at a coarse level of detail.
- Entire lifecycle
$${W_{LC}} = {n_s}{A_f}({w_{pud}} + {t_d}{w_d})$$
DDM sensitivities
Properties
Object Name
- Name of the object in Rt
- Allowable characters are upper-case and lower-case letters, numbers, and underscore (“_”).
- The name is unique and case-sensitive.
Display Output
- Determines whether the model is allowed to print messages to the Output Pane.
Pre Use W Intensity
- \({w_{pud}}\) = The water intensity of the materials used (pre-use) for a corresponding building function in L/m2
Number Storeys
- \({n_s}\) = The number of storeys in a building
- \({A_f}\) = The building footprint area of building in m2
Annual W Intensity
- \({w_d}\) = The annual water intensity for a given building operation type in L/m2/year
Design Life
- \({t_d}\) = The design life of the building in years
Output
- \({W}\) = The lifecycle water usage in a building in L
- The output is an automatically generated generic response object, which takes the object name of the model plus “Response”.
Right-click Menu
Remove