Model Form
- This model produces the lifecycle water usage in a building at a coarse level of detail.
- Entire lifecycle
$${GWP_{LC}} = {i_n}({E_{total}}-{E_{OP}}) + {E_{OP}}{i_{OP}}$$
DDM sensitivities
Properties
Object Name
- Name of the object in Rt
- Allowable characters are upper-case and lower-case letters, numbers, and underscore (“_”).
- The name is unique and case-sensitive.
Display Output
- Determines whether the model is allowed to print messages to the Output Pane.
Life Cycle Energy
- \({E_{total}}\) = The entire life cycle energy for a building in J
Operation Energy
- \({E_{OP}}\) = The total energy used over the operation stage of buildingās life cycle J
GWP Intensity Operation
- \({i_{OP}}\) = The GWP intensity of operational phases in kgCO2e/ J
GWP Intensity Non Operation
- \({i_n}\) = The GWP intensity of non operational phases in kgCO2e/ J
Output
- \({E_{GWP}}\) = The lifecycle energy usage in a building regarded to global warming potential in J
- The output is an automatically generated generic response object, which takes the object name of the model plus “Response”.